Selantes Elásticos Produtos Químicos
Os químicos de seladores elásticos incluem polímeros MS (poliéteres terminados em silano), pré-polímeros de poliuretano, polímeros de silicone (PDMS, reticuladores) e plastificantes para vedação de juntas de construção, envidraçamento de fachadas, seladores sanitários e preenchimento de lacunas industriais com acomodação de movimento de 25–50%.
Dispersão de Selante Acrílico SAD-50
CAS 9003-01-4
MOQ: 200 kg
Extenssor de Silicato de Alumínio AS-200 (Hidratado)
CAS 1335-30-4
MOQ: 500 kg
Base de Fita Autoadesiva de Borracha Butílica BR-100
CAS 9010-85-9
MOQ: 200 kg
Borracha Butílica Sólida IIR-268
CAS 9010-85-9
MOQ: 200 kg
Carbonato de Cálcio PCC Grau Leve (Precipitado)
CAS 471-34-1
MOQ: 500 kg
Negro de Carbono Special Black 4 (Baixo Jetness)
CAS 1333-86-4
MOQ: 200 kg
Óleo de Mamona (Poliol de Grau Industrial)
CAS 8001-79-4
MOQ: 200 kg
Plastificante Ftalato de Dioctila (DOP)
CAS 117-81-7
MOQ: 1000 kg
Sílica Pirogênica Hidrofóbica RX-200 (Tratada com PDMS, Modificada em Superfície)
CAS 68611-44-9
MOQ: 15 kg
Hidroxietil Celulose HEC QP-100MH Modificada Hidrofobicamente
CAS 9004-62-0
MOQ: 25 kg
Solução IPBC 10% (3-Iodo-2-propinilo Butilo Carbamato)
CAS 55406-53-6
MOQ: 25 kg
Polímero MS de baixa viscosidade STP-E10
CAS 132207-32-0
MOQ: 100 kg
Pré-polímero de Selante PU à Base de MDI NC-8010
MOQ: 200 kg
Adesivo de Polímero MS Grau STP-G10
MOQ: 200 kg
Polímero MS STP-E30 (Terminado em sililo)
CAS 132207-32-0
MOQ: 100 kg
Pré-polímero de Vedante de Poliuretano NC-4035
CAS 9009-54-5
MOQ: 100 kg
Agente de Cura de Polissulfeto Pasta MnO2
CAS 1313-13-9
MOQ: 50 kg
Polímero de Polissulfeto LP-32 (Alto PM)
CAS 63148-67-4
MOQ: 200 kg
Polímero Selante de Polissulfeto LP-2
CAS 63801-95-6
MOQ: 100 kg
Emulsão Acrílica Pura PA-30
CAS 9003-01-4
MOQ: 200 kg
Polímero Base de Silicone RTV-1 201
CAS 63148-62-9
MOQ: 200 kg
Componente Base RTV-2 de Silicone | Alta Resistência
CAS 63148-62-9
MOQ: 100 kg
Polímero STPE (Poliéter Terminado em Silano) Baixo Módulo
MOQ: 200 kg
Componente B do Agente de Reticulação de Silicone RTV-2
MOQ: 200 kg
Perguntas Frequentes — Selantes Elásticos Produtos Químicos
What are the differences between silicone, PU, and MS polymer sealants?
Silicone sealants have the best UV and temperature resistance — standard for structural glazing and high-movement facade joints — but are difficult to paint over. Polyurethane (PU) sealants are paintable with excellent mechanical strength, preferred for floor joints and expansion joints in concrete. MS polymer sealants combine PU's paintability with silicone-level weather resistance — the most versatile and fastest-growing type in construction.
What crosslinkers and catalysts are used in silicone sealant formulations?
Acetoxy (acid-cure) silicone sealants use acetoxysilane crosslinkers — the classic shower sealant with characteristic acetic acid odor. Oxime-cure (neutral cure) silicones use methylethylketoxime (MEKO) crosslinkers — standard for construction and glazing. Alkoxy-cure silicones use alkoxysilane crosslinkers for paintability and adhesion to concrete. Tin (DBTDL) or titanate catalysts accelerate cure.
How is movement capability rated for elastic sealants?
Elastic sealant movement capacity (±12.5%, ±20%, or ±25%) is measured by ISO 9047 or ASTM C719 — cured specimens are cyclically extended and compressed while monitoring adhesion. Joint design is critical: standard rule is sealant bead width should be twice the expected movement. High-movement sealants (MS, hybrid, or high-quality silicone) are specified for curtain wall and façade applications.
What is the proper joint design for elastic sealant applications?
For ±25% movement, joint width is typically 10–25 mm with depth = ½ × width up to 12 mm maximum. Backer rod (closed-cell PE foam) controls depth and prevents three-side adhesion (which causes failure). Hourglass bead profile distributes strain evenly. Bond-breaker tape is used in fillet joints. Primer is required on porous (concrete) and some low-energy (PP, PTFE) substrates.
How are construction sealants tested for façade applications?
ASTM C920 (and ISO 11600) classify sealants by Type, Grade, Class (movement %), and Use. Class 25 / Class 50 sealants undergo cyclic adhesion-in-peel testing. EN 15651 covers façade, glazing, and sanitary applications in Europe. Pull-off adhesion testing is performed at the project site to verify substrate-specific bonding before warranty — a mandatory step on commercial curtain-wall projects.
What is the difference between one-part and two-part elastic sealants?
One-part sealants (silicone, MS polymer, PU) cure by atmospheric moisture — simple to use but cure depth is limited to ~5 mm/24 h. Two-part sealants (PU, polysulfide) cure throughout regardless of joint depth — preferred for deep joints and large bead applications. Two-part systems require precise mixing and have shorter pot life. Industrial applications and immersion-service joints typically specify two-part for full-depth cure assurance.
Procura matérias-primas específicas?
Nossa equipe técnica pode recomendar os produtos químicos certos para suas necessidades de formulação — amostras disponíveis.