Selladores Elásticos Productos Químicos
Los químicos de selladores elásticos incluyen polímeros MS (poliéteres terminados en silano), prepolímeros de poliuretano, polímeros de silicona (PDMS, entrecruzadores) y plastificantes para sellado de juntas de construcción, acristalamiento de fachadas, selladores sanitarios y relleno de espacios industriales con acomodación de movimiento de 25–50%.
Dispersión de Sellador Acrílico SAD-50
CAS 9003-01-4
MOQ: 200 kg
Extensor de Silicato de Aluminio AS-200 (Hidratado)
CAS 1335-30-4
MOQ: 500 kg
Base de Cinta Autoadhesiva de Caucho Butílico BR-100
CAS 9010-85-9
MOQ: 200 kg
Caucho Butílico Sólido IIR-268
CAS 9010-85-9
MOQ: 200 kg
Carbonato de Calcio PCC Grado Ligero (Precipitado)
CAS 471-34-1
MOQ: 500 kg
Negro de Carbón Special Black 4 (Bajo Jetness)
CAS 1333-86-4
MOQ: 200 kg
Aceite de Ricino (Poliol de Grado Industrial)
CAS 8001-79-4
MOQ: 200 kg
Plastificante Ftalato de Dioctilo (DOP)
CAS 117-81-7
MOQ: 1000 kg
Sílice Pirogénica Hidrofóbica RX-200 (Tratada con PDMS, Modificada en Superficie)
CAS 68611-44-9
MOQ: 15 kg
Hidroxietil Celulosa HEC QP-100MH Modificada Hidrofóbicamente
CAS 9004-62-0
MOQ: 25 kg
Solución IPBC 10% (3-Yodo-2-propinilo Butilo Carbamato)
CAS 55406-53-6
MOQ: 25 kg
Polímero MS de baja viscosidad STP-E10
CAS 132207-32-0
MOQ: 100 kg
Prepolímero de Sellador PU a Base de MDI NC-8010
MOQ: 200 kg
Adhesivo de Polímero MS Grado STP-G10
MOQ: 200 kg
Polímero MS STP-E30 (Silil-terminado)
CAS 132207-32-0
MOQ: 100 kg
Prepolímero de Sellador de Poliuretano NC-4035
CAS 9009-54-5
MOQ: 100 kg
Agente Curante de Polisulfuro Pasta MnO2
CAS 1313-13-9
MOQ: 50 kg
Polímero de Polisulfuro LP-32 (Alto PM)
CAS 63148-67-4
MOQ: 200 kg
Polímero Sellador de Polisulfuro LP-2
CAS 63801-95-6
MOQ: 100 kg
Emulsión Acrílica Pura PA-30
CAS 9003-01-4
MOQ: 200 kg
Polímero Base de Silicona RTV-1 201
CAS 63148-62-9
MOQ: 200 kg
Componente Base RTV-2 de Silicona | Alta Resistencia
CAS 63148-62-9
MOQ: 100 kg
Polímero STPE (Poliéter Terminado en Silano) Bajo Módulo
MOQ: 200 kg
Componente B de Agente Entrecruzador de Silicona RTV-2
MOQ: 200 kg
Preguntas Frecuentes — Selladores Elásticos Productos Químicos
What are the differences between silicone, PU, and MS polymer sealants?
Silicone sealants have the best UV and temperature resistance — standard for structural glazing and high-movement facade joints — but are difficult to paint over. Polyurethane (PU) sealants are paintable with excellent mechanical strength, preferred for floor joints and expansion joints in concrete. MS polymer sealants combine PU's paintability with silicone-level weather resistance — the most versatile and fastest-growing type in construction.
What crosslinkers and catalysts are used in silicone sealant formulations?
Acetoxy (acid-cure) silicone sealants use acetoxysilane crosslinkers — the classic shower sealant with characteristic acetic acid odor. Oxime-cure (neutral cure) silicones use methylethylketoxime (MEKO) crosslinkers — standard for construction and glazing. Alkoxy-cure silicones use alkoxysilane crosslinkers for paintability and adhesion to concrete. Tin (DBTDL) or titanate catalysts accelerate cure.
How is movement capability rated for elastic sealants?
Elastic sealant movement capacity (±12.5%, ±20%, or ±25%) is measured by ISO 9047 or ASTM C719 — cured specimens are cyclically extended and compressed while monitoring adhesion. Joint design is critical: standard rule is sealant bead width should be twice the expected movement. High-movement sealants (MS, hybrid, or high-quality silicone) are specified for curtain wall and façade applications.
What is the proper joint design for elastic sealant applications?
For ±25% movement, joint width is typically 10–25 mm with depth = ½ × width up to 12 mm maximum. Backer rod (closed-cell PE foam) controls depth and prevents three-side adhesion (which causes failure). Hourglass bead profile distributes strain evenly. Bond-breaker tape is used in fillet joints. Primer is required on porous (concrete) and some low-energy (PP, PTFE) substrates.
How are construction sealants tested for façade applications?
ASTM C920 (and ISO 11600) classify sealants by Type, Grade, Class (movement %), and Use. Class 25 / Class 50 sealants undergo cyclic adhesion-in-peel testing. EN 15651 covers façade, glazing, and sanitary applications in Europe. Pull-off adhesion testing is performed at the project site to verify substrate-specific bonding before warranty — a mandatory step on commercial curtain-wall projects.
What is the difference between one-part and two-part elastic sealants?
One-part sealants (silicone, MS polymer, PU) cure by atmospheric moisture — simple to use but cure depth is limited to ~5 mm/24 h. Two-part sealants (PU, polysulfide) cure throughout regardless of joint depth — preferred for deep joints and large bead applications. Two-part systems require precise mixing and have shorter pot life. Industrial applications and immersion-service joints typically specify two-part for full-depth cure assurance.
¿Busca materias primas específicas?
Nuestro equipo técnico puede recomendar los químicos adecuados para sus requisitos de formulación — muestras disponibles.